" Water, Oil and Coal "

​Laboratory Instruments & Technical Supplies

+6221 22921988 (Hunting)        +62813 8017 4489, +62819 1187 3766 

 cs@ciptakaryamaju.com 

Pt Cipta Karya Maju

our PRODUCTS

          Model                                                                                      5E-C5808 Automatic Calorimeter   


Conforms to Method                      AS 1038.5, ASTM D5865, ASTM D4809, ASTM E711, BIS 1350, BS EN 15400, GB/T 213,GB/T 30727, ISO 1928, ISO 9831,

                                                      ISO 18125 


Precision (1g Benzoic Acid)                                                                                              0.05% RSD *

Measuring range                                                                                                             Up to 40MJ/kg

Heat Capacity Stability                                                                                              ≤0.2% within one year

Temp.Resolution                                                                                                                 0.0001℃

Control Ability                                                                                                            2 Units/ 1 PC available

Analysis Time per Sample                                                                                                    8mins

Test Per Hour                                                                  Single control                                                                                Double control


                                                                                             Up to 7                                                                                          Up to 15

Jacket Type                                                                                                               Isoperibol and Adiabatic

Ignition Method                                                                                                       Patented Laser Technology

Bomb Identification                                                                                                                   Yes

Balance Connection                                                                                                              Available

Network Connection                                                                                                              Available

Bucket Filling                                                                                                                        Automatic

Oxygen Filling                                                                                                                       Automatic

Bomb Vessel Lifting                                                                                                              Automatic

Structure                                                                                                                               Benchtop

Power Supply                                                                                           Single phase, AC220V±10%, 50/60Hz, ≤500w

Net Weight                                                                                                                               50kg

Dimensions(L×W×H)                                                                                                 480mm×500mm×420mm

             *Test Condition: 1. Ambient temp.20℃±1℃,humidity75%±5%  2.No strong interference source nearby  3.Clean water circuit with distilled water

         

Optional Configuration:
Standard Configuration:

1. Patented laser ignition technology allowing easier and faster sample preparation, no ignition wire or cotton thread is needed
2. 8min fast analysis for one sample
3. Automatic oxygen vessel lifting
4. Automatic oxygen charging and venting
5. Intelligent temperature control of the jacket and the water tank, the water constant temperature stability of the jacket reaches to 0.02℃
6. Easy and convenient touch screen operation
7. Small space occupied with compact design
8. Intelligent diagnosis and safety protection function


New!

​Lens paper
Pellet press
Halogen Resistant Oxygen Vessel


​Main analyzer
Standard CV bomb -2 Units
Crucibles
Benzoic Acid
O-ring kit
Tool kit


Specification:

​5E-C5808 is CKIC new generation calorimeter which is used to determine the calorific value of solid and liquid combustibles including oil, coal, coke, foodstuffs and biomass products. The calorific value is a crucial characteristic for each substance, also the key point to calculate the price of coal, so it will directly affect the economic benefits of the customers. This technique is widely applied in power plants, coal mines, metallurgy, chemical industry, commercial inspection, scientific research, etc.

Features:

5E-C5808 Automatic Calorimeter